RPM, WFG. 3194 Hickory Blvd. Hudson, NC 28638 Phone: 828-728-8266
MATERIAL SAFETY DATA SHEET
Polyester Cream Hardener/Polyester Catalyst,
Benzoyl Peroxide 47.5-50.0 94-36-0 Combustible when dry:
* Refer to 29 CFR 1910.1000, subpartZ.
Also see TLV for Chemical Substances and Physical Agents in the Work Environment
APPEARANCE: Red, white blue, green or raspberry
FLASHPOINT: 184F/84C Seta Flash Closed cup
FIRE EXTINGUISHING MEDIA: Carbon Dioxide, Dry Chemical, Foam
SPECIAL FIRE FIGHTING PROCEDURES: Fight like a fuel oil fire. Cool fire exposed
containers with water spray. Firefighter should wear OSHA/NIOSH approved self-
UNUSUAL FIRE AND EXPLOSION HAZARD: Closed containers exposed to high
temperatures, such as fire conditions may rupture.
SECTION V - HEALTH HAZARD/TOXICOLOGICAL PROPERTIES
OVEREXPOSURE EFFECTS: ACUTE EFFECTS:
EYES: Contact with eyes can cause irritation, redness, tearing, blurred vision,
SKIN: Contact with skin can cause irritation, (minor itching, burning and/or
redness), Dermatitis, defatting may be readily absorbed thru the skin.
INHALATION: Inhalation of vapors can cause nasal and respiratory irritation,
dizziness, weakness, fatigue, nausea, headache, possible unconsciousness and/or
asphyxiation. Aspiration of material into lungs may result in chemical
INGESTION: Ingestion can cause gastrointestinal irritation, nausea, vomiting,
CHRONIC EFFECTS:
Overexposure to this material has apparently been known to cause the following
effects in lab animals: skin damage and appendages.
Benzoyl Peroxide has caused tumorigenic effects in laboratory animals. PRIMARY ROUTES OF EXPOSURE: skin, inhalation FIRST AID: INHALATION: If inhaled, remove victim from exposure to a well-ventilated area.
Make them comfortably warm, but not hot. Use oxygen or artificial respiration as
SKIN: For skin contact, wash promptly with soap and excess water. EYES: For eye contact, flush promptly with excess water for at least fifteen INGESTION: If ingested, do not induce vomiting. Give victim a glass of water.
CONDITIONS TO AVOID: Open flames, sparks, heat, electrical and static discharge.
INCOMPATIBILITY MATERIALS TO AVOID: Strong acids, alkalis, oxidizers.
HAZARDOUS DECOMPOSITION PRODUCTS: Carbon Dioxide, Carbon Monoxide and Carbon.
HAZARDOUS POLYMERIZATION: Will not occur.
SECTION VII - SPILL AND DISPOSAL PROCEDURE
SPILLS, LEAK OR RELEASE: Ventilate area. Remove all possible sources of
ignition. Avoid prolonged breathing of vapor. Contain spill with inert
WASTE DISPOSAL: Dispose of in accordance with local, state, and federal
RESPIRATORY PROTECTION: If component TLV limits are exceeded, use NIOSH/MSHA
approved respirator to remove vapors. Use an air-supplied respirator if
VENTILATION: Use adequate ventilation in volume and pattern to keep TLV/PEL
below recommended levels. Explosion-proof ventilation may be necessary.
PROTECTIVE GLOVES: To prevent prolonged exposure use rubber gloves; solvents may
EYE PROTECTION: Safety Glasses or goggles with splash guards or side shields.
OTHER PROTECTIVE EQUIPMENT: Wear protective clothing as required to prevent skin
SECTION IX - HANDLING AND STORAGE PRECAUTIONS
STORAGE AND HANDLING: Use with adequate ventilation. Avoid contact with eyes and
skin. Avoid breathing vapors. Do not store the product above 100F/38C. Do not
flame, cut, braze weld or melt empty containers. Keep the product away from
heat, open flame, and other sources of ignition. Avoid contact with
strong acids, alkalis and oxidizers.
SHIPPING INFORMATION: Please comply with DOT regulations in USA
Trace amounts of some chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm may be present in this product.
This product contains the following toxic chemicals subject to the reporting
requirements of the Emergency Planning and Community Right-To-Know Act of 1986
CHEMICAL NAME____________CAS_______________%BY WGT
THIS INFORMATION MUST BE INCLUDED IN ALL MSDS'8 THAT ARE COPIED AND DISTRIBUTED
IARC = International Agency for Research on Cancer
ACGIH = American Conference of Governmental Industrial Hygienists
NIOSH - National Institute of Occupational Safety and Health
IMPORTANT: WHILE THE DESCRIPTIONS, DATA AND INFORMATION CONTAINED HEREIN ARE PRESENTED IN GOOD FAITH AND BELIEVED TO BE ACCURATE, IT IS PROVIDED FOR YOUR GUIDANCE ONLY. BECAUSE MANY FACTORS MAY AFFECT PROCESSING OR APPLICATION/USE, WE RECOMMEND THAT YOU PERFORM AN ASSESSMENT TO DETERMINE THE SUITABILITY OF A PRODUCT FOR YOUR PARTICULAR PURPOSE PRIOR TO USE. NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED, DATA OR INFORMATION SET FORTH. IN NO CASE SHALL THE DESCRIPTIONS, INFORMATION, OR DATA PROVIDED BE CONSIDERED A PART OF OUR TERMS AND CONDITIONS OF SALE. FURTHER, THE DESCRIPTIONS, DATA AND INFORMATION FURNISHED HEREUNDER ARE GIVEN GRATIS. NO OBLIGATION OR LIABILITY FOR THE DESCRIPTION, DATA AND INFORMATION GIVEN ARE ASSUMED. ALL SUCH BEING GIVEN AND ACCEPTED AT YOUR RISK.
Médecine Nucléaire - Centre HospitalierLes modalités du traitement des cancers thyroïdiens diffé-Les données scintigraphiques et échographiques permet-renciés dépendent dune part du stade évolutif et de lex-tent la réalisation de ponctions à laiguille fine en vu duntension de la maladie et, dautre part, des facteurs pronos-verdict cytologique dont le score dépend étro
OFFICIAL RULES 2013 Lance®/Atlanta Falcons/Publix Sweepstakes NO PURCHASE NECESSARY. A PURCHASE OR PAYMENT OF ANY KIND WILL NOT INCREASE YOUR CHANCES OF WINNING. VOID OUTSIDE OF GEORGIA AND ALABAMA. Eligibility: Open only to legal residents of Georgia and Alabama who are twenty-one (21) years of age or older as of the date of entry. Employees or agents of Snyder’s-Lance, Inc.,